Li G, Wang X, Li Q, Yang J, Liu X, Qi W, Guo J, De. Development of an immunochromatographic strip for rapid detection of H7 subtype avian influenza viruses. Virol J. 2021 Apr 7;18(1):68
Background: H7N9 avian influenza virus (AIV) including highly and low pathogenic viruses have been detected in China since 2013. H7N9 AIV has a high mortality rate after infection in humans, and most human cases have close contacted with poultry in the live poultry market. Therefore, it is necessary to develop a rapid point-of-care testing (POCT) technique for H7N9 AIV detection.
Methods: The H7N9 AIV was inactivated and purified, and was used as the antigen to immunize BALB/c. Twelve H7-HA specific monoclonal antibodies (McAbs) were produced through the hybridoma technique. The McAb 10A8 was conjugated with colloid gold as detecting antibody; McAb 9B6 was dispensed on the nitrocellulose membran as the capture test line and the Goat-anti mouse IgG antibody was dispensed as control line respectively. The immunochromatographic strip was prepared.
Results: The analysis of ELISA and virus neutralization test showed that the obtained McAbs specifically recognized H7 HA. Based on the prepared strip, the detection of H7 AIV was achieved within 10 min. No cross-reaction occurred between H7 AIVs and other tested viruses. The detection limit of the strip for H7 was 2.4 log10EID50/0.1 mL for chicken swab samples.
Conclusion: The McAbs were specific for H7 and the immunochromatographic strip developed in this study was convenient, rapid and reliable for the detection of H7 AIV. The strip could provide an effective method for the rapid and early detection of H7 AIV.
Methods: The H7N9 AIV was inactivated and purified, and was used as the antigen to immunize BALB/c. Twelve H7-HA specific monoclonal antibodies (McAbs) were produced through the hybridoma technique. The McAb 10A8 was conjugated with colloid gold as detecting antibody; McAb 9B6 was dispensed on the nitrocellulose membran as the capture test line and the Goat-anti mouse IgG antibody was dispensed as control line respectively. The immunochromatographic strip was prepared.
Results: The analysis of ELISA and virus neutralization test showed that the obtained McAbs specifically recognized H7 HA. Based on the prepared strip, the detection of H7 AIV was achieved within 10 min. No cross-reaction occurred between H7 AIVs and other tested viruses. The detection limit of the strip for H7 was 2.4 log10EID50/0.1 mL for chicken swab samples.
Conclusion: The McAbs were specific for H7 and the immunochromatographic strip developed in this study was convenient, rapid and reliable for the detection of H7 AIV. The strip could provide an effective method for the rapid and early detection of H7 AIV.
See Also:
Latest articles in those days:
- T cell help is a limiting factor for rare anti-influenza memory B cells to reenter germinal centers and generate potent broadly neutralizing antibodies 20 hours ago
- Wild birds drive the introduction, maintenance, and spread of H5N1 clade 2.3.4.4b high pathogenicity avian influenza viruses in Spain, 2021-2022 20 hours ago
- [preprint]FluNexus: a versatile web platform for antigenic prediction and visualization of influenza A viruses 21 hours ago
- Salpingitis and multiorgan lesions caused by highly pathogenic avian influenza A(H5N1) virus in a cat associated with consumption of recalled raw milk in California 21 hours ago
- Detection of highly pathogenic avian influenza A(H5N1) virus 2.3.4.4b in alpacas 21 hours ago
[Go Top] [Close Window]


