Bekking C, et al. Evaluation of bioaerosol samplers for the detection and quantification of influenza virus from artificial aerosols and influenza virus-infected ferrets. Influenza Other Respir Viruses. 2019 Sep 21
BACKGROUND:
Bioaerosol sampling devices are necessary for the characterization of infectious bioaerosols emitted by naturally-infected hosts with acute respiratory virus infections. Assessment of these devices under multiple experimental conditions will provide insight for device use.
OBJECTIVES:
The primary objective of this study was to assess and compare bioaerosol sampling devices using a) an in vitro, environmentally-controlled artificial bioaerosol system at a range of different RH conditions and b) an in vivo bioaerosol system of influenza virus-infected ferrets under controlled environmental conditions. Secondarily, we also sought to examine the impact of NSAIDs on bioaerosol emission in influenza virus-infected ferrets to address its potential as a determinant of bioaerosol emission.
METHODS:
We examined the performance of low and moderate volume bioaerosol samplers for the collection of viral RNA and infectious influenza virus in vitroand in vivo using artificial bioaerosols and the ferret model of influenza virus infection. The following samplers were tested: the polytetrafluoroethylene filter (PTFE filter), the 2-stage National Institute of Occupational Safety and Health cyclone sampler (NIOSH cyclone sampler) and the 6-stage viable Andersen impactor (Andersen impactor).
RESULTS:
The PTFE filter and NIOSH cyclone sampler collected similar amounts of viral RNA and infectious virus from artificially-generated aerosols under a range of relative humidities (RH). Using the ferret model, the PTFE filter, NIOSH cyclone sampler and the Andersen impactor collected up to 3.66 log10 copies of RNA/L air, 3.84 log10 copies of RNA/L air and 6.09 log10 copies of RNA/L air respectively at peak recovery. Infectious virus was recovered from the PTFE filter and NIOSH cyclone samplers on the peak day of viral RNA recovery.
CONCLUSION:
The PTFE filter and NIOSH cyclone sampler are useful for influenza virus RNA and infectious virus collection and may be considered for clinical and environmental settings.
Bioaerosol sampling devices are necessary for the characterization of infectious bioaerosols emitted by naturally-infected hosts with acute respiratory virus infections. Assessment of these devices under multiple experimental conditions will provide insight for device use.
OBJECTIVES:
The primary objective of this study was to assess and compare bioaerosol sampling devices using a) an in vitro, environmentally-controlled artificial bioaerosol system at a range of different RH conditions and b) an in vivo bioaerosol system of influenza virus-infected ferrets under controlled environmental conditions. Secondarily, we also sought to examine the impact of NSAIDs on bioaerosol emission in influenza virus-infected ferrets to address its potential as a determinant of bioaerosol emission.
METHODS:
We examined the performance of low and moderate volume bioaerosol samplers for the collection of viral RNA and infectious influenza virus in vitroand in vivo using artificial bioaerosols and the ferret model of influenza virus infection. The following samplers were tested: the polytetrafluoroethylene filter (PTFE filter), the 2-stage National Institute of Occupational Safety and Health cyclone sampler (NIOSH cyclone sampler) and the 6-stage viable Andersen impactor (Andersen impactor).
RESULTS:
The PTFE filter and NIOSH cyclone sampler collected similar amounts of viral RNA and infectious virus from artificially-generated aerosols under a range of relative humidities (RH). Using the ferret model, the PTFE filter, NIOSH cyclone sampler and the Andersen impactor collected up to 3.66 log10 copies of RNA/L air, 3.84 log10 copies of RNA/L air and 6.09 log10 copies of RNA/L air respectively at peak recovery. Infectious virus was recovered from the PTFE filter and NIOSH cyclone samplers on the peak day of viral RNA recovery.
CONCLUSION:
The PTFE filter and NIOSH cyclone sampler are useful for influenza virus RNA and infectious virus collection and may be considered for clinical and environmental settings.
See Also:
Latest articles in those days:
- Expansion of influenza A(H1N1)pdm09 NA:S247N viruses with reduced susceptibility to oseltamivir, Catalonia, Spain, and in Europe, July to October 2025 12 minute(s) ago
- Inactivation of avian influenza virus in yogurt made from raw milk 13 minute(s) ago
- Elucidating the nature of the interactions of oseltamivir with the 2D model of influenza A virus lipid envelope 14 minute(s) ago
- Trends in influenza vaccination uptake in a universally insured population in the united states, 2017-2023 15 minute(s) ago
- Autoantibodies neutralizing type I IFNs in a fatal case of H5N1 avian influenza 19 minute(s) ago
[Go Top] [Close Window]